CGC# 1519549
A Fountain Enterprises Company
Fountain Window & Door
Co. Lic. # WD210
 
 

Fountain Window And Door

Retrofit installation procedure for windows

  • Protect furniture/electronics/ with painters plastic
  • Protect flower beds with canvas tarps, glass, stucco, etc.
  • Removal of existing window unit.
  • Remove existing bucks and necessary stucco
  • Clean down to substrate, expose necessary substrate for work
  • Apply concrete block sealant, to all substrate exposed, for additional layer of water intrusion protection
  • Install proper buck as per manufacturers spec and Florida Building 5th edition
  • Seal under new bucks with sika-flex type poly-urethane sealant
  • Maximum shim space .025
  • Apply sealant to body of window, outer buck face, inner flange of window unit
  • Set window in sealant into opening, shim as needed
  • Drill substrate and install ?X 3 ?(if solid filled CBS, 2 ? if hollow) 410 crete-flex stainless tapcon fasteners, minimum substrate penetration is 1.25
  • Stucco outside, drywall inside
  • Apply sealant to inside and outside of unit
  • Apply Loxon primer to new stucco, apply body paint supplied by owner
  • Apply drywall primer inside & paint to match as supplied by owner.
  • Remove protective barriers inside and outside
  • Clean work area Installation will meet or exceed Florida Building Code 5th Edition & manufacturer installation specs.

    Note: Drywall dust will be blown through unit from outside, no way to completely prevent this from occurring. We will clean every day and clean our mess as we move forward. Mother Nature has her own way of spreading the mess.